Iris Management Suite
Technical Guide V1.7C 4/11/07
25
For lower security systems a longer polling time can be used.
By default, Polling Overdue and Polling Restore for each remote IRIS dialler
are only reported by the Polling Engine acting as Main for that dialler. Some
ARC systems cannot differentiate Polling Overdue or Polling OK messages
seen on the serial links from the Main and Backup Polling Engines and this
mechanism prevents potential confusion at the ARC in situations where, for
example, there was a transient network problem and the IRIS dialler failed to
connect to Main and so polled to the Backup.
In circumstances where there has been a major failure at the site where the
Main Polling Engine is located and no polls can get through, if the ARC
wishes the Secondary Polling Engine to report Polling Overdue and Polling
OK, this can be enabled by setting the Polling Accept option for that Polling
Engine to “All Diallers”.